Part Number Hot Search : 
C1501 11EWA SB152M 4J1685J G12864 PEB2086 C74VC MAX10
Product Description
Full Text Search
 

To Download KA78MXX02 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 www.fairchildsemi.com
KA78MXX
3-Terminal 0.5A Positive Voltage Regulator
Features
* * * * * Output Current up to 0.5A Output Voltages of 5, 6, 8, 12, 15, 18, 24V Thermal Overload Protection Short Circuit Protection Output Transistor Safe Operating Area (SOA) Protection
Description
The KA78MXX series of three terminal positive regulators are available in the TO-220/D-PAK package with several fixed output voltages making it useful in a wide range of applications.
TO-220
GND
1
D-PAK
GND
1
1. Input 2. GND 3. Output
Internal Block Diagram
INPUT 1
SERIES PASS ELEMENT
OUTPUT 3
CURRENT GENERATOR
SOA PROTECTION
R1
STARTING CIRCUIT
REFERENCE VOLTAGE
ERROR AMPLIFIER
R2 THERMAL PROTECTION
GND 2
Rev. 1.0.5
(c)2002 Fairchild Semiconductor Corporation
KA78MXX
Absolute Maximum Ratings
Parameter Input Voltage (for VO = 5V to 18V) (for VO = 24V) Thermal Resistance Junction-Cases (Note1) TO-220 (Tc = +25C) Thermal Resistance Junction-Air (Note1,2) TO-220 (Ta = +25C) D-PAK (Ta = +25C) Operating Junction Temperature Range Storage Temperature Range
Note: 1. Thermal resistance test board Size: 76.2mm * 114.3mm * 1.6mm(1S0P) JEDEC standard: JESD51-3, JESD51-7 2. Assume no ambient airflow
Symbol VI VI RJC RJA TOPR TSTG
Value 35 40 2.5 66 92 0 ~ +150 -65 ~ +150
Unit V V C/W C/W C C
Electrical Characteristics (KA78M05/KA78M05R)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=10V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ =+25C VO IO = 5 to 350mA VI = 7 to 20V IO = 200mA TJ =+25C VI= 7 to 25V VI = 8 to 25V Conditions Min. 4.8 4.75 Typ. 5 5 4.0 -0.5 40 80 2 300 700 Max. 5.2 5.25 100 50 100 50 6.0 0.5 0.8 mA V Unit
Line Regulation (Note3) Load Regulation (Note3) Quiescent Current Quiescent Current Change
VO VO IQ IQ V/T VN RR VD ISC IPK
mV mV mA
IO = 5mA to 0.5A, TJ = +25C IO = 5mA to 200mA, TJ =+25C TJ = +25C IO = 5mA to 350mA IO = 200mA VI = 8 to 25V IO = 5mA TJ = 0 to +125C f = 10Hz to 100kHz f = 120Hz, IO = 300mA VI = 8 to 18V, TJ = +25C TJ = +25C, IO = 500mA TJ = +25C, VI = 35V TJ = +25C
Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
mV/C
V/Vo
dB V mA mA
Note: 3. Load and line regulation are specified at constant junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
2
KA78MXX
Electrical Characteristics (KA78M06/KA78M06R) (Continued)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=11V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ = +25C VO IO = 5 to 350mA VI = 8 to 21V IO = 200mA TJ =+25C VI = 8 to 25V VI = 9 to 25V Conditions Min. 5.75 5.7 Typ. 6 6 4.0 -0.5 45 80 2 300 700 Max. 6.25 6.3 100 50 120 60 6.0 0.5 0.8 mA V Unit
Line Regulation (Note1) Load Regulation (Note1) Quiescent Current Quiescent Current Change
VO VO IQ IQ V/T VN RR VD ISC IPK
mV mV mA
IO = 5mA to 0.5A, TJ =+25C IO = 5mA to 200mA, TJ =+25C TJ =+25C IO = 5mA to 350mA IO = 200mA VI = 9 to 25V IO = 5mA TJ = 0 to +125C f = 10Hz to 100kHz f = 120Hz, IO = 300mA VI = 9 to 19V, TJ = +25C TJ =+25C, IO = 500mA TJ= +25C, VI = 35V TJ =+25C
Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
mV/C
V/Vo
dB V mA mA
Note: 1. Load and line regulation are specified at constant, junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
3
KA78MXX
Electrical Characteristics (KA78M08/KA78M08R) (Continued)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=14V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ = +25C VO IO = 5 to 350mA VI= 10.5 to 23V IO = 200mA TJ =+25C VI = 10.5 to 25V VI = 11 to 25V Conditions Min. 7.7 7.6 Typ. 8 8 4.0 -0.5 52 80 2 300 700 Max. 8.3 8.4 100 50 160 80 6.0 0.5 0.8 mA V Unit
Line Regulation (Note1) Load Regulation (Note1) Quiescent Current Quiescent Current Change
VO VO IQ IQ
mV mV mA
IO = 5mA to 0.5A, TJ = +25C IO = 5mA to 200mA, TJ = +25C TJ = +25C IO = 5mA to 350mA IO = 200mA VI = 10.5 to 25V IO = 5mA TJ = 0 to +125C f = 10Hz to 100kHz f = 120Hz, IO = 300mA VI = 11.5 to 21.5V, TJ = +25C TJ =+25C, IO = 500mA TJ =+25C, VI= 35V TJ =+25C
Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
RR VN RR VD ISC IPK
mV/C
V/Vo
dB V mA mA
Note: 1. Load and line regulation are specified at constant, junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
4
KA78MXX
Electrical Characteristics (KA78M12/KA78M12R) (Continued)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=19V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ = +25C VO IO = 5 to 350mA VI = 14.5 to 27V IO = 200mA TJ = +25C VI= 14.5 to 30V VI = 16 to 30V Conditions Min. 11.5 11.4 Typ. 12 12 4.1 -0.5 75 80 2 300 700 Max. 12.5 12.6 100 50 240 120 6.0 0.5 0.8 mA V Unit
Line Regulation (Note1) Load Regulation (Note1) Quiescent Current Quiescent Current Change
VO VO IQ IQ V/T VN RR VD ISC IPK
mV mV mA
IO = 5mA to 0.5A, TJ = +25C IO = 5mA to 200mA, TJ =+25C TJ=+25C IO = 5mA to 350mA IO = 200mA VI = 14.5 to 30V IO = 5mA TJ = 0 to +125C f = 10Hz to 100kHz f = 120Hz, IO = 300mA VI = 15 to 25V, TJ = +25C TJ =+25C, IO = 500mA TJ= +25C, VI = 35V TJ = +25C
Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
mV/C
V/Vo
dB V mA mA
Note: 1. Load and line regulation are specified at constant, junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
5
KA78MXX
Electrical Characteristics (KA78M15) (Continued)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=23V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ =+25C VO IO = 5 to 350mA VI = 17.5 to 30V IO = 200mA TJ = +25C VI = 17.5 to 30V VI = 20 to 30V Conditions Min. 14.4 14.25 Typ. 15 15 4.1 -1 100 70 2 300 700 Max. 15.6 15.75 100 50 300 150 6.0 0.5 0.8 mA V Unit
Line Regulation (Note1) Load Regulation (Note1) Quiescent Current Quiescent Current Change
VO VO IQ IQ V/T VN RR VD ISC IPK
mV mV mA
IO = 5mA to 0.5A, TJ =+25C IO = 5mA to 200mA, TJ =+25C TJ =+25C IO = 5mA to 350mA IO = 200mA VI = 17.5 to 30V IO = 5mA TJ = 0 to +125C f = 10Hz to 100kHz f = 120Hz, IO = 300mA VI = 18.5 to 28.5V, TJ = +25C TJ =+25C, IO = 500mA TJ= +25C, VI = 35V TJ = +25C
Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
mV/C
V/Vo
dB V mA mA
Note: 1. Load and line regulation are specified at constant, junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
6
KA78MXX
Electrical Characteristics (KA78M18) (Continued)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=26V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ = +25C VO IO = 5 to 350mA VI = 20.5 to 33V IO = 200mA TJ =+25C VI = 21 to 33V VI = 24 to 33V Conditions Min. 17.3 17.1 Typ. 18 18 4.2 -1.1 100 70 2 300 700 Max. 18.7 18.9 100 50 360 180 6.0 0.5 0.8 mA mV/C V/Vo dB V mA mA V Unit
Line Regulation (Note1) Load Regulation (Note1) Quiescent Current Quiescent Current Change Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
VO V IQ IQ V/T VN RR VD ISC IPK
mV mV mA
IO = 5mA to 0.5A, TJ = +25C IO = 5mA to 200mA, TJ = +25C TJ =+25C IO = 5mA to 350mA IO = 200mA VI = 21 to 33V IO = 5mATJ = 0 to 125C f = 10Hz to 100kHz f = 120Hz, IO=300mA , VI=22 to 32V TJ = +25C TJ = +25C, IO=500mA TJ = +25C, VI=35V TJ = +25C
Note: 1. Load and line regulation are specified at constant, junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
7
KA78MXX
Electrical Characteristics (KA78M24) (Continued)
(Refer to the test circuits, 0 < TJ < +125C, IO=350mA, VI=33V, unless otherwise specified, CI =0.33F, CO=0.1F) Parameter Output Voltage Symbol TJ = +25C VO IO = 5 to 350mA VI = 27 to 38V IO = 200mA TJ = +25C VI = 27 to 38V VI = 28 to 38V Conditions Min. 23 22.8 Typ. 24 24 4.2 -1.2 170 70 2 300 700 Max. 25 25.2 100 50 480 240 6 0.5 0.8 mA V Unit
Line Regulation Load Regulation Quiescent Current Quiescent Current Change
VO VO IQ IQ V/T VN RR VD ISC IPK
mV mV mA
IO = 5mA to 0.5A, TJ =+25C IO = 5mA to 200mA, TJ =+25C TJ = +25C IO = 5mA to 350mA IO = 200mA VI = 27 to 38V IO = 5mA TJ = 0 to +125C f = 10Hz to 100kHz f = 120Hz, IO = 300mA VI = 28 to 38V, TJ = +25C TJ =+25C, IO = 500mA TJ = +25 C, VI = 35V TJ = +25C
Output Voltage Drift Output Noise Voltage Ripple Rejection Dropout Voltage Short Circuit Current Peak Current
mV/C
V
dB V mA mA
Note: 1. Load and line regulation are specified at constant, junction temperature. Change in Vo due to heating effects must be taken into account separately. Pulse testing with low duty is used.
8
KA78MXX
Typical Applications
VI CI
1
3
KA78MXX
2
VO CO
0.1F
0.3F
Figure 1. Fixed Output Regulator
VI CI
1
3
KA78MXX
2
0.33F
CO
0.1F
IO
VXX IO
Vxx IO = R1 +IO
R1
Figure 2. Constant Current Regulator Notes: 1. To specify an output voltage, substitute voltage value for "XX" 2. Although no output capacitor is needed for stability, it does improve transient response. 3. Required if regulator is located an appreciable distance from power Supply filter
VI CI
1
3
KA78MXX
2
0.33F
VO VXX R1
CO
0.1F
IO
IR1 5IO VO = VXX (1+R2/R1) +IOR2
R2
Figure 3. Circuit for Increasing Output Voltage
9
KA78MXX
VI CI
1
3
KA78M05
2
0.33F
VO CO
7 2 3
10k 0.1F
6
LM741
4
Figure 4. Adjustable Output Regulator (7 to 30V)
13V < VI < 25V
VI C1
1
KA78M05
2
3
R4 910 R5 9.1k
VO
VXX
0.33F
6
-7 < -VI < 17V
7 _2 LM741 + 3 R3 R1 4
C2
0.1F 10k
VO = Vxx
R4 R1
Figure 5. 0.5 to 10V Regulator
10
KA78MXX
Mechanical Dimensions
Package Dimensions in millimeters
TO-220
9.90 0.20 4.50 0.20
1.30 0.10
2.80 0.10
(8.70) o3.60 0.10
(1.70)
1.30 -0.05
+0.10
9.20 0.20
(1.46)
13.08 0.20
(1.00)
(3.00)
15.90 0.20
1.27 0.10
1.52 0.10
0.80 0.10 2.54TYP [2.54 0.20] 2.54TYP [2.54 0.20]
10.08 0.30
18.95MAX.
(3.70)
(45 )
0.50 -0.05
+0.10
2.40 0.20
10.00 0.20
11
KA78MXX
Mechanical Dimensions (Continued)
Package Dimensions in millimeters
D-PAK
6.60 0.20 5.34 0.30 (0.50) (4.34) (0.50)
0.70 0.20
2.30 0.10 0.50 0.10
0.60 0.20
6.10 0.20
2.70 0.20
9.50 0.30
0.91 0.10
0.80 0.20
MAX0.96 2.30TYP [2.300.20]
0.76 0.10 2.30TYP [2.300.20]
0.89 0.10
0.50 0.10 1.02 0.20 2.30 0.20
(0.70)
(0.90) (0.10) (3.05)
6.10 0.20
9.50 0.30
2.70 0.20
(2XR0.25)
0.76 0.10
12
(1.00)
6.60 0.20 (5.34) (5.04) (1.50)
MIN0.55
KA78MXX
Ordering Information
Product Number KA78M05 KA78M06 KA78M08 KA78M12 KA78M15 KA78M18 KA78M24 KA78M05R KA78M06R KA78M08R KA78M12R D-PAK 0 ~ +125C TO-220 Package Operating Temperature
13
KA78MXX
DISCLAIMER FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN; NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS. LIFE SUPPORT POLICY FAIRCHILD'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user.
www.fairchildsemi.com 11/12/02 0.0m 001 Stock#DSxxxxxxxx 2002 Fairchild Semiconductor Corporation
2. A critical component in any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.


▲Up To Search▲   

 
Price & Availability of KA78MXX02

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X